Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Optogalvanic spectroscopy with microplasma sources: Current status and development towards a lab on a chip
Uppsala University, Division of Microsystems Technology, Uppsala, Sweden; Uppsala University, Ångström Space Technology Centre, Uppsala, Sweden. (ÅSTC)
Uppsala University, Division of Microsystems Technology, Uppsala, Sweden; Uppsala University, Ångström Space Technology Centre, Uppsala, Sweden. (IRF)
Uppsala University, Division of Microsystems Technology, Uppsala, Sweden. (ÅSTC)
Försvarshögskolan, Militärvetenskapliga institutionen (MVI), Avdelningen för ledningsvetenskap och militärteknik (ALM), Sektionen för militärtekniska system (MteS). Uppsala University, Division of Microsystems Technology, Uppsala, Sweden; Uppsala University, Ångström Space Technology Centre, Uppsala, Sweden. (ÅSTC)ORCID-id: 0000-0002-0501-0887
Visa övriga samt affilieringar
2016 (Engelska)Ingår i: Journal of Micromechanics and Microengineering, ISSN 0960-1317, E-ISSN 1361-6439, Vol. 26, nr 10, artikel-id 104003Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Miniaturized optogalvanic spectroscopy (OGS) shows excellent prospects for becoming a highly sensitive method for gas analysis in micro total analysis systems. Here, a status report on the current development of microwave-induced microplasma sources for OGS is presented, together with the first comparison of the sensitivity of the method to conventional single-pass absorption spectroscopy. The studied microplasma sources are stripline split-ring resonators, with typical ring radii between 3.5 and 6mm and operation frequencies around 2.6 GHz. A linear response (R2 = 0.9999), and a stability of more than 100 s are demonstrated when using the microplasma source as an optogalvanic detector. Additionally, saturation effects at laser powers higher than 100 mW are observed, and the temporal response of the plasma to periodic laser perturbation with repletion rates between 20 Hz and 200 Hz are studied. Finally, the potential of integrating additional functionality with the detector is discussed, with the particular focus on a pressure sensor and a miniaturized combustor to allow for studies of solid samples.

Ort, förlag, år, upplaga, sidor
2016. Vol. 26, nr 10, artikel-id 104003
Nyckelord [en]
split-ring resonator, microplasma sources, optogalvanic spectroscopy
Nationell ämneskategori
Rymd- och flygteknik
Forskningsämne
Försvarssystem
Identifikatorer
URN: urn:nbn:se:fhs:diva-7344DOI: 10.1088/0960-1317/26/10/104003ISI: 000384028900003OAI: oai:DiVA.org:fhs-7344DiVA, id: diva2:1190751
Projekt
OGIIRTillgänglig från: 2018-03-15 Skapad: 2018-03-15 Senast uppdaterad: 2019-08-26Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Sturesson, Peter

Sök vidare i DiVA

Av författaren/redaktören
Sturesson, Peter
Av organisationen
Sektionen för militärtekniska system (MteS)
I samma tidskrift
Journal of Micromechanics and Microengineering
Rymd- och flygteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 135 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf